Showing results: 31 - 45 of 58 items found.
-
Eltel Industries
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Series FT -
GE Digital Energy
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
Ponovo Power Co., Ltd.
For primary injection testings, PONOVO has been providing users, various testing equipment, including CT/PT test set, Single phase universal test test upto 250A and 1000A, etc. CT/PT tester could be used for testing all kinds of CT testing, with additional PT testing functions.
-
T&R Test Equipment Ltd.
Our primary current injection test sets cover from 750A through to 6000A. Available in single phase, testing applications include testing and timing of under and over current relays, circuit breakers and CT ratio testing.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.
-
BUX -
Altanova Group
The current boosters allow performing tests up to 2000A, 3000A and 5000A. The option is made of a module, which incorporates a power transformer, which generates a low-voltage, high current output and a metering CT, which measures the output current and sends the metering to eKAM.
-
Askida CT -
Alithya
Askida CT changes the way automated tests are carried out. It is the only platform on the market that lets you do true end-to-end testing automation without requiring deep technical skills. You can easily define your testing strategy and convert your manual tests into automated ones in one simple click.
-
SP-6103 -
Shanghai Powoo Industry Develop Group Limited
- Single phase energy meter test bench - auto-calibration system - accuracy class: 0.1/0.2 class - Standard CT; 0.01/0.02 - output voltage: 0-220V9240V option); range: 0-120% - fine adjustment: 0.01% - output current: 0-100A; (option for 200A)- fine adjustment: 0.0001A (min)
-
6000 Bird Dog Plus -
Spinlab Utility Instrumentation, Inc.
This new and exciting true 3 phase Bird Dog Plus enables you to determine the accuracy of any meter in the field--from Form 1 through Form 17. Electronic sensors allow you to automate the test to gain the highest possible accuracy. The process is fast, simple, and much less expensive than a portable test board for the meter test and still perform ratio & burden tests on your CTs (CT Tester).
-
HTCT-300 -
Lisun Electronics Inc.
Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.
-
7 Series -
Powermetrix Systems
We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.
-
iCT1 -
Altanova Group
iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
ABB Ltd.
Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.
-
GF106T -
Beijing GFUVE Electronics Co.,Ltd.
It is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.